MIOT HomeMIOT Home
中弘VRF空调Ultra
#qdhkl.airc.a19s

中弘VRF空调Ultra

urn:miot-spec-v2:device:air-conditioner:0000A004:qdhkl-a19s:1
Language
Service tree
Air Conditioner
#2 · air-conditioner
4 properties1 actions

Properties

Switch Status
#1 · on
Format
bool
Access
R / W / N
Value
—
Mode
#2 · mode
Format
uint8
Access
R / W / N
Value
0Auto
1Cool
2Dry
3Refreshing
4Fan
5Auto Dehumidification
6Care Sleep
8Heat
12Ventilation
13Constant Temperature And Humidity Control
9FloorHeating
14T-and-H-control
15Intelligence
10IntenseHeat
Device Fault
#3 · fault
Format
uint8
Access
R / N
Value
0No Faults
Target Temperature
#4 · target-temperature
Format
float
Access
R / W / N
Value
16 ~ 32, step 0.5 celsius

Actions

Toggle
#1 · toggle
Fan Control
#3 · fan-control
3 properties

Properties

Fan Level
#2 · fan-level
Format
uint8
Access
R / W / N
Value
0Auto
1Quiet
2Low
3Mid Low
4Medium
5Mid High
6High
7Turbo
8Power
Horizontal Position
#3 · horizontal-position
Format
uint8
Access
R / W / N
Value
0Swing
1Left Sweep
2Freeze Left
3Middle Left
4Freeze Right
5Right Sweep
6Middle Right
7Stop
Vertical Position
#4 · vertical-position
Format
uint8
Access
R / W / N
Value
0Swing
1Top Rating
2Freeze Top
3Middle Top
4Freeze Down
5Lower Rating
6Middle Down
7Stop
Environment
#4 · environment
1 properties

Properties

Temperature
#7 · temperature
Format
float
Access
R / N
Value
-30 ~ 100, step 0.1 celsius
custom
#5 · custom
19 properties4 actions

Properties

#1 · capabilityset
Format
string
Access
R / N
Value
—
#2 · errorcode
Format
string
Access
R / N
Value
—
windspeed
#3 · windspeed
Format
uint16
Access
R / N / W
Value
0 ~ 100, step 1
#4 · set-sleepmode-param
Format
string
Access
W
Value
—
#5 · get-sleepmode-config
Format
string
Access
R / N
Value
—
#6 · quick-set
Format
string
Access
W
Value
—
#7 · quick-set-read
Format
string
Access
R / N
Value
—
#8 · ac-brand
Format
string
Access
R / N
Value
—
#9 · gear-dh-set
Format
uint8
Access
R / N / W
Value
1Dry
2Moderate
3Moist
#11 · water-temp-set
Format
uint8
Access
R / N / W
Value
1Manual
2Auto
3Linked
#12 · water-t-set
Format
float
Access
R / N / W
Value
5 ~ 60, step 0.5 celsius
#13 · target-room-temp
Format
float
Access
R / N / W
Value
16 ~ 30, step 0.5 celsius
#16 · out-water-temp-set
Format
float
Access
R / N
Value
0 ~ 255, step 0.1 celsius
#17 · freon-switch-set
Format
string
Access
W
Value
—
#18 · water-switch-set
Format
string
Access
W
Value
—
#19 · fan-direct
Format
uint8
Access
R / N / W
Value
1Dual-air-outlet
2Upward-airflow
3Below-airflow
#20 · indoor-dh-switch-set
Format
uint8
Access
R / N / W
Value
1Dry
2Moderate
3Moist
#21 · freon-switch-read
Format
string
Access
R / N
Value
—
water-switch-read
#22 · water-switch-read
Format
string
Access
R / N
Value
—

Actions

raise-one-degree
#1 · raise-one-degree
down-one-degree
#2 · down-one-degree
fan-speed-up
#3 · fan-speed-up
fan-speed-down
#4 · fan-speed-down