MIOT HomeMIOT Home
松下浴霸FV-RB29NL1
#pesgd.bhf_light.w

松下浴霸FV-RB29NL1

urn:miot-spec-v2:device:bath-heater:0000A028:pesgd-w:1
Language
Service tree
Light
#2 · light
2 properties

Properties

Light
#1 · on
Format
bool
Access
R / W / N
Value
—
Warm Light
#2 · flex-switch
Format
bool
Access
R / W / N
Value
—
PTC Bath Heater
#3 · ptc-bath-heater
5 properties

Properties

Status
#1 · status
Format
bool
Access
R / N
Value
—
Device Fault
#4 · fault
Format
uint8
Access
R / N
Value
0No Faults
1Motor error
2Heater Temperature sensor error
3RF communication error
4SUB unit communication signal error
6Gas sensor error
7Inlet Port Temperature sensor error
Mode
#2 · mode
Format
uint8
Access
R / W / N
Value
0Idle
2Ventilate
3CoolDry
4HotDry
5NanoeX
6SmtDeodorize
7SmartHeat
Left Time
#3 · left-time
Format
uint16
Access
R / N
Value
0 ~ 1440, step 1 minutes
Temperature
#6 · temperature
Format
int8
Access
R / N
Value
-16 ~ 70, step 1 celsius
Fan Control
#4 · fan-control
2 properties

Properties

Fan Level
#3 · fan-level
Format
uint8
Access
R / W / N
Value
0OFF
1High
2Low
Wind Direction
#1 · wind-direction
Format
uint8
Access
R / W / N
Value
0Fixed
1Auto
2Fixed90
special-set
#5 · special-set
5 properties

Properties

Timer Setting
#1 · timer-mode-set
Format
uint8
Access
R / N / W
Value
0Off
1Timer15 Min
2Timer30 Min
3Timer1 Hour
4Timer3 Hour
5Timer6 Hour
6Continuous
Wind Type
#2 · fan-category
Format
uint8
Access
R / N / W
Value
0Off
1Concentrate
2Diffusion
Light Color
#3 · light-color
Format
uint8
Access
R / N / W
Value
0Close
1CoolLight
2WarmLight
SMART DEODORIZATION
#4 · smart-odors-state
Format
uint8
Access
R / N
Value
0OFF
1Sensing
2Deodorizing
3NanoeX
#5 · set-temper-display
Format
uint8
Access
R / N
Value
30 ~ 45, step 1 celsius