MIOT HomeMIOT Home
尼特利水泵
#niteli.pump.nlwp1

尼特利水泵

urn:miot-spec-v2:device:pump:0000A092:niteli-nlwp1:1
Language
Service tree
Pump
#2 · pump
17 properties4 actions

Properties

Power
#1 · on
Format
bool
Access
N / R / W
Value
—
Pause
#2 · pause
Format
bool
Access
N / R / W
Value
—
Mode
#3 · mode
Format
uint8
Access
N / R / W
Value
0Constant
1Wave
2Wave Tide
3Wave Random
Feeding Switch
#4 · feeding
Format
bool
Access
N / R / W
Value
—
Constant Flow Level
#5 · const-level
Format
uint8
Access
N / R / W
Value
1 ~ 30, step 1 gear
Wave Mode Level
#6 · wave-level
Format
uint8
Access
N / R / W
Value
1 ~ 30, step 1 gear
Feeding Time
#7 · feeding-time
Format
uint8
Access
N / R / W
Value
5 ~ 60, step 5 minutes
Timer Scenario
#8 · schedule
Format
string
Access
N / R / W
Value
—
Screen Sleep
#9 · display-sleep
Format
bool
Access
N / R / W
Value
—
Buzzer
#10 · buzzer
Format
bool
Access
N / R / W
Value
—
Key Lock
#11 · key-lock
Format
bool
Access
N / R / W
Value
—
Alarm Sensitivity
#12 · alarm-sensitivity
Format
uint8
Access
N / R / W
Value
0 ~ 10, step 1
Remaining Feeding Time
#13 · remaining-time
Format
uint16
Access
N / R
Value
0 ~ 3900, step 1 seconds
Speed
#14 · speed
Format
uint16
Access
N / R
Value
0 ~ 9999, step 1
Fault
#15 · fault
Format
uint8
Access
N / R
Value
0No Faults
1Iref
2Ocp
3Undefined
4Over Voltage
5Under Voltage
6Loss Phase
7Undefined
8Stall Or Start
9Bus Comm
model
#16 · model
Format
string
Access
N / R
Value
—
source
#17 · control-source
Format
uint8
Access
N / R
Value
0App
1Panel
2Cloud
3Online
4Report
5Timer
6Offline

Actions

Combine: Constant+Level
#1 · const
Input
#3Modeuint8#5Constant Flow Leveluint8
Combine: Wave+Level
#2 · wave
Input
#3Modeuint8#5Constant Flow Leveluint8#6Wave Mode Leveluint8
Combine: Feeding+Level
#3 · feeding
Input
#4Feeding Switchbool#7Feeding Timeuint8
Action: Pause
#4 · pause
Input
#2Pausebool