MIOT HomeMIOT Home
叮零智能宠物喂食器
#madv.feeder.fjpet2

叮零智能宠物喂食器

urn:miot-spec-v2:device:pet-feeder:0000A06C:madv-fjpet2:1
Language
Service tree
Pet Feeder
#2 · pet-feeder
9 properties2 actions1 events

Properties

Device Fault
#1 · fault
Format
uint8
Access
R / N
Value
0No Faults
1Stock
Status
#3 · status
Format
uint8
Access
R / N
Value
0Power
1Battery
Mode
#4 · mode
Format
uint8
Access
R / W / N
Value
0Normal
1Slow
Feeding Measure
#5 · feeding-measure
Format
uint8
Access
Value
1 ~ 60, step 1
Pet Food Left Level
#6 · pet-food-left-level
Format
uint8
Access
R / N
Value
1Normal
2Empty
Feeding Type
#8 · feeding-type
Format
uint8
Access
Value
0Remote
1Key
2Plan
Current Time
#10 · current-time
Format
uint32
Access
Value
0 ~ 4294967295, step 1
Current Time
#11 · current-time
Format
uint8
Access
Value
0 ~ 255, step 1
Current Time
#12 · current-time
Format
uint8
Access
Value
0Success
1Err1
2Err2
3Feeding
4Close

Actions

Pet Food Out
#1 · pet-food-out
Input
#5Feeding Measureuint8
Weigh Manual Calibrate
#2 · weigh-manual-calibrate

Events

Food Out Complete
#1 · food-out-complete
Arguments
#8Feeding Typeuint8#5Feeding Measureuint8#10Current Timeuint32#11Current Timeuint8#12Current Timeuint8
Indicator Light
#3 · indicator-light
1 properties

Properties

Switch Status
#1 · on
Format
bool
Access
R / W / N
Value
—
Physical Control Locked
#5 · physical-controls-locked
1 properties

Properties

Physical Control Locked
#1 · physical-controls-locked
Format
bool
Access
R / W / N
Value
—
Battery
#7 · battery
1 properties

Properties

Battery Level
#1 · battery-level
Format
uint8
Access
R / N
Value
0 ~ 100, step 1 percentage
Desiccant
#9 · desiccant
1 properties1 actions

Properties

Desiccant Left Level
#1 · desiccant-left-level
Format
uint8
Access
R / N
Value
0 ~ 100, step 1 percentage

Actions

Reset Desiccant Life
#1 · reset-desiccant-life
feed-plan
#8 · feed-plan
6 properties4 actions

Properties

plan-ctrl
#2 · plan-ctrl
Format
bool
Access
R / N / W
Value
—
edit-plan
#6 · edit-plan
Format
string
Access
Value
—
del-plan
#7 · del-plan
Format
uint16
Access
Value
1 ~ 255, step 1
#8 · feed-plan
Format
string
Access
R / N
Value
—
#9 · skiped-plan
Format
string
Access
R / N
Value
—
skip-plan
#10 · skip-plan
Format
uint16
Access
Value
1 ~ 255, step 1

Actions

update
#2 · update
Input
#6edit-planstring
del
#3 · del
Input
#7del-planuint16
skip
#4 · skip
Input
#10skip-planuint16
re-open
#5 · re-open
Input
#10skip-planuint16